IVF centre in Goa
Consultations in Panjim · Margao · Mapusa · Vasco
Call
Page 50 of 72Genesis ART Textbook
Part 4: Cryopreservation and vitrification · Day 10
Page 50 of 72

Oocyte vitrification

On this page you will learn

Why oocytes are difficult

Pages 45 to 47 explained that vitrification turns water into a glass rather than ice by combining high concentrations of cryoprotectant with very fast cooling. The mature (MII) oocyte is the hardest test of that idea. It is one of the largest cells in the body, so it has a lot of water and a small surface for that water to leave by. Its meiotic spindle, which holds the chromosomes ready for fertilisation, is sensitive to cooling and can depolymerise. Its zona and membrane change after exposure to some stresses. All of this explains why oocyte freezing became routine only once vitrification replaced slow freezing (page 46).

Oocytes are usually vitrified after denudation (page 25), so that you can see that they are mature. Only MII oocytes are vitrified as a rule; the reasons for vitrifying a GV or MI oocyte are rare and are decided by the senior embryologist.

The two solutions

Most protocols use two steps.

ES is a slow step measured in minutes; VS is a fast step measured in seconds, because the concentrated solution becomes toxic if contact is long. Your laboratory's validated protocol, based on the instructions for the kit in use, sets the exact times and temperatures. Learn it as written and do not improvise.

At the bench: vitrifying an oocyte

On Day 10 you vitrify your two straws under supervision. Practise the movements with discarded material first.

  1. Label the carrier devices and fill the insulated box with fresh liquid nitrogen. Confirm the patient, the number of oocytes and the device count with your witness.
  2. Bring the solutions to the temperature in your protocol and set out a dish or plate with drops of ES and VS.
  3. Pick up the oocytes in a minimum of culture medium and place them in ES. Start the timer. Watch the oocyte shrink and then partly re-expand.
  4. When the ES time is complete, move the oocytes through the VS drops, rinsing to dilute any carried-over ES. Start the second timer.
  5. Load the oocytes on to the carrier tip in the smallest volume you can, often a thin film around the cells. Remove excess liquid with the pipette.
  6. Plunge the device straight into liquid nitrogen within the VS time limit, then cap or close it under nitrogen.
  7. Transfer to the storage tank and record times, operator, witness and storage address.

The two habits that matter most are a small volume and a fast plunge. A large drop cools slowly and may form ice. A slow hand lets VS toxicity build. The warming side of the process, which matters even more, is on page 52.

What to watch

Who has oocytes vitrified

Oocyte vitrification is used for fertility preservation before treatment for cancer or other illness that may harm the ovary, when sperm is not available on the day of pick-up, when too many oocytes are collected to inseminate all of them, and for planned preservation. The clinical choice belongs to the doctor and the couple; your role is to make each oocyte count.

Common errors

Check yourself

  1. Name two features of the MII oocyte that make it sensitive to cryopreservation.
  2. What does a sugar such as sucrose do in the vitrification solution?
  3. Why is time in ES measured in minutes and time in VS in seconds?
  4. What two habits at loading matter most, and why?

Contents and reading plan

Questions on this page

Can immature oocytes be vitrified?

Technically yes, but the standard practice is to vitrify mature MII oocytes. Immature oocytes may be matured in culture first (page 59); this is a senior decision.

Why does the oocyte shrink and then re-expand in ES?

Water leaves faster than cryoprotectant enters, so the cell shrinks first. As cryoprotectant enters, water follows it back in and the volume recovers.

Does it matter which carrier device is used?

Each device has a validated loading volume and handling method. Use the device and protocol your lab has validated, and do not mix methods.

The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.