IVF centre in Goa
Consultations in Panjim · Margao · Mapusa · Vasco
Call
Page 11 of 72Genesis ART Textbook
Part 1: Andrology, semen preparation and IUI · Day 2
Page 11 of 72

Density gradient centrifugation

On this page you will learn

The principle

Density gradient centrifugation (DGC) separates cells by their density. A colloid of silica particles, coated with silane so that it is not toxic to sperm, is prepared at two densities. The lighter layer sits on top of the denser layer. Semen is placed on top and the tube is centrifuged.

Mature, morphologically normal sperm with condensed nuclei are dense, and motile sperm move actively through the layers; they pass through both layers and collect in a pellet at the bottom. Immature germ cells, leucocytes, dead and abnormal sperm and debris are less dense and stay at the interfaces. The WHO laboratory manual (6th edition, 2021) describes this method in detail.

Why use it

Relative centrifugal force

Protocols give centrifugation in g, the relative centrifugal force (RCF). Your centrifuge may show revolutions per minute (rpm). The same rpm gives different g in centrifuges with different rotor radii. Convert using the formula RCF = 1.118 x 10-5 x r x rpm2, where r is the radius in centimetres from the centre of the rotor to the bottom of the tube. Write the correct rpm for each centrifuge on a label beside it.

At the bench

  1. Bring the gradient colloid and the wash medium to the temperature your protocol specifies (usually 37 °C in an incubator) before you start. Cold colloid harms sperm.
  2. Label a sterile conical tube on its body with two identifiers, with a witness.
  3. Pipette the denser layer into the bottom of the tube. Then carefully layer the lighter layer on top, running it slowly down the side so that a sharp interface forms. Do not mix the layers.
  4. Assess the liquefied semen (pages 6-7), then gently layer the semen on top of the upper layer. Do not overload: a very large volume of semen on a small gradient separates poorly. Use extra gradients for large samples.
  5. Centrifuge with a balanced tube opposite, in a sealed bucket or capped tube, at the force and time in your protocol (the WHO manual describes a range of 300 to 400 g for 15 to 30 minutes).
  6. Harvest the pellet carefully. Either remove the upper layers from the top down with a fresh pipette, or pass a fresh pipette through the layers and collect the pellet from the bottom, without dragging debris from the interfaces.
  7. Resuspend the pellet in fresh medium and centrifuge again to wash out the colloid (a lower force for a shorter time is usual).
  8. Remove the supernatant and resuspend the final pellet in a small, defined volume of medium.
  9. Assess the final preparation (page 14) and record everything with times.

Using an incubator correctly

If the harvested sperm will wait before use, keep them in a medium suited to the conditions: HEPES-buffered medium in air, or bicarbonate-buffered medium in a CO2 incubator. Keep them at room temperature or 37 °C as your protocol says; prolonged warm incubation can increase oxidative stress.

Common errors

Check yourself

  1. Why do mature, normal sperm reach the bottom of the gradient?
  2. Convert in words: why does the same rpm give different g in two centrifuges?
  3. Describe two safe ways to harvest the pellet.
  4. Why is the pellet washed after the gradient spin?

Contents and reading plan

Questions on this page

Is density gradient better than swim-up?

Neither is better for every sample. Gradients usually recover more motile sperm and suit poorer samples; swim-up gives a very clean preparation from good samples. Page 13 explains how to choose.

Why must the colloid be warmed?

Sudden cooling damages sperm membranes and motility, so the colloid and media are brought to the protocol temperature before the sample is added.

The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.