IVF centre in Goa
Consultations in Panjim · Margao · Mapusa · Vasco
Call
Page 16 of 72Genesis ART Textbook
Part 2: The IVF laboratory, oocytes and ICSI · Day 3
Page 16 of 72

Lab design, airflow and air quality

On this page you will learn

Welcome to Part 2

Part 1 covered the andrology bench. From this page you move into the IVF laboratory, where oocytes and embryos spend several days outside the body. An embryo in culture has no immune system, no blood supply to clear toxins and no mother's body to buffer changes. Everything in the room that can reach the culture dish matters: temperature, light, gas and the air itself.

Layout of the laboratory

A well-designed laboratory follows the path of the work. The oocyte pick-up room sits next to the laboratory, joined by a pass-through hatch, so that tubes of follicular fluid travel a short distance and stay warm. The embryo transfer room is also close by. Andrology usually has its own space, so that semen samples and their microbes are kept away from oocyte and embryo work.

Surfaces are smooth and easy to clean. Cleaning uses water and cleaning agents approved for embryo work, because many ordinary disinfectants and perfumes give off fumes that are toxic to embryos.

Airflow and particles

Air entering the laboratory passes through high-efficiency particulate (HEPA) filters, which remove dust and microbes. The laboratory is kept at a slightly higher pressure than the rooms around it, so that when a door opens, clean air flows out rather than dirty air flowing in. Particle counts are measured at intervals, and the results are kept as part of the quality records.

Volatile organic compounds

Volatile organic compounds (VOCs) are chemicals that evaporate at room temperature: from paints, glues, new furniture, cleaning products, perfumes, vehicle exhaust and even some plastics. HEPA filters do not stop them. They are removed by activated-carbon and similar chemical filters in the air handling system and, in many laboratories, inside the incubators too. VOCs are linked with poorer embryo development, so the laboratory treats them seriously.

Light, temperature and humidity

Room temperature and humidity are kept stable, because the heated stages and incubators work most reliably in a steady room. Bright light, especially at the blue end of the spectrum, can harm gametes and embryos, so lighting is dimmed and exposure under the microscope is kept short.

At the bench

  1. Enter through the gowning area: change into laboratory clothing and shoes, cover hair, and wash hands.
  2. Do not wear perfume, scented lotion, hair spray or nail varnish on laboratory days. Do not bring food, cardboard boxes or outdoor bags inside.
  3. Keep doors closed. Open the laboratory door only when you need to.
  4. Before work, check the room readings your laboratory logs (temperature, humidity and pressure) and note anything out of range.
  5. Unpack new consumables outside the laboratory and allow new items to air out as your protocol requires.
  6. Clean workstations at the start and end of each session with the approved agent only.

Any building work, painting or new furniture near the laboratory must be planned with the laboratory team, because fumes can affect culture for days afterwards.

Common errors

Check yourself

  1. Why is an embryo in culture more vulnerable than adult tissue?
  2. What do HEPA filters remove, and what do they not remove?
  3. Why is the laboratory kept at a slightly higher air pressure than the corridor?
  4. Name four everyday sources of volatile organic compounds and how you would keep them out.

Contents and reading plan

Questions on this page

Why can I not wear perfume in the IVF laboratory?

Perfumes release volatile organic compounds, which can reach culture media and harm embryos. Filters reduce them, but the safest source to control is you.

Does the laboratory have to be a full cleanroom?

Laboratories differ in design, but all aim for filtered air, positive pressure, low VOCs and stable conditions. Follow the standards and protocol of the laboratory you work in.