IVF centre in Goa
Consultations in Panjim · Margao · Mapusa · Vasco
Call
Page 8 of 72Genesis ART Textbook
Part 1: Andrology, semen preparation and IUI · Day 1
Page 8 of 72

Vitality and morphology

On this page you will learn

Vitality

Vitality tells you whether immotile sperm are dead or alive. It matters most when few sperm are moving: many live but immotile sperm suggest a structural tail defect, whereas mostly dead sperm (necrozoospermia) point to a different set of causes. Test vitality soon after liquefaction, preferably within 30 minutes and no later than one hour after collection.

Eosin-nigrosin

Live sperm have intact membranes that keep eosin out. Dead sperm take up the stain. Nigrosin gives a dark background so that unstained heads stand out.

  1. Mix equal volumes of well-mixed semen and eosin-nigrosin stain and wait about 30 seconds.
  2. Make a thin smear, air-dry it, and examine it under oil at x1000 with brightfield optics.
  3. Count at least 200 spermatozoa: white or unstained heads are live; red or dark-pink heads are dead. A sperm with only a faint pink neck region is counted as live.
  4. Repeat with a second smear and compare the replicates.

A useful internal check: the proportion of live sperm should never be lower than the proportion of motile sperm, because a moving sperm is alive. If it is, one of the two tests is wrong.

Hypo-osmotic swelling (HOS) test

In a hypo-osmotic solution, water enters sperm with intact membranes and the tail swells and coils. The sperm are not stained, so this test is used when you need to select a live but immotile sperm for ICSI (page 30).

Morphology

Sperm morphology is assessed on a stained smear, using the strict (Tygerberg) criteria adopted in the WHO laboratory manual (6th edition, 2021). It is the most subjective part of semen analysis, which is why regular training and quality control matter so much (page 15).

At the bench: the smear

  1. Adjust the volume of semen to the concentration: a small drop for a normal count, more for a low count. Very low or very viscous samples may need washing first.
  2. Use the feathering technique: draw the drop along the slide with the edge of a second slide held at an angle, giving an even layer where sperm do not overlap.
  3. Make two smears, air-dry, then fix.
  4. Stain with the Papanicolaou method (the WHO-preferred stain) or a validated rapid stain, following your laboratory's timings exactly.
  5. Examine under oil at x1000 and assess at least 200 spermatozoa per slide.

What counts as normal

Under strict criteria, any borderline form is classed as abnormal. For abnormal sperm, record which regions are affected: head, midpiece, tail, or excess residual cytoplasm. Some laboratories also calculate a teratozoospermia index, the average number of defects per abnormal sperm.

Some uniform defects are important to recognise because they affect treatment choice: for example globozoospermia, where the head is round and lacks an acrosome, and sperm with very large heads and multiple tails. Report them clearly; the doctor will discuss their meaning.

Round cells and leucocytes

On a wet preparation, "round cells" may be white blood cells (leucocytes) or immature germ cells. They look alike. A peroxidase stain, or immunocytochemistry for a leucocyte marker, tells them apart. A high leucocyte count may suggest inflammation or infection, and can harm sperm by producing reactive oxygen species.

Common errors

Check yourself

  1. Why should the proportion of live sperm never be lower than the proportion of motile sperm?
  2. When would you use the HOS test instead of eosin-nigrosin?
  3. Describe the normal sperm head under strict criteria.
  4. How do you tell leucocytes from immature germ cells?

Contents and reading plan

Questions on this page

Is a low normal-forms result a reason for ICSI?

Morphology is one part of the picture. The decision between IUI, IVF and ICSI is made by the doctor from all the results and the couple's history (pages 27 and 66).

Why is morphology so variable between laboratories?

It is a subjective judgement on a stained smear. Strict criteria, consistent staining, regular training and external quality control reduce the variation.

The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.