Lab orientation, safety and witnessing
On this page you will learn
- how an ART laboratory is laid out and how you behave inside it
- how to protect yourself from body fluids, chemicals, centrifuges and cold
- how to protect gametes and embryos from you
- what witnessing is and how a witnessed step is done
Two kinds of safety
In an ART laboratory you protect two things at once. You protect yourself and your colleagues from biological, chemical and physical hazards. And you protect the gametes and embryos from you: from heat loss, light, fumes, contamination and, above all, from being mixed up. Every rule you meet on this page serves one of these two aims.
Layout and behaviour
The andrology room, where semen is analysed and prepared, is kept separate from the IVF laboratory, where oocytes and embryos are handled. The IVF laboratory has controlled airflow and filtered air (page 16), and access is limited to the people who work there.
- Change into laboratory clothing, cap, mask and clean footwear before entering the IVF laboratory.
- Wear no perfume, aftershave, scented lotion or nail polish: volatile chemicals can harm embryos.
- Wash your hands, then wear powder-less, non-toxic gloves. Change gloves between patients.
- Keep mobile phones, food and drink outside.
- Move calmly. Doors, quick movements and crowds disturb airflow and incubator stability.
- Speak quietly and only as needed while a colleague is working at the microscope.
Protecting yourself
Body fluids
Treat every semen sample, follicular fluid and blood sample as potentially infectious, whatever the screening result. Make sure your hepatitis B vaccination is complete. Use mechanical pipetting devices only; never pipette by mouth. Cover cuts. Wipe spills at once with the laboratory's approved disinfectant and report them.
Sharps and glass
Glass Pasteur pipettes, needles and broken slides go straight into a rigid sharps container. Never recap a needle.
Chemicals
Fixatives and stains used for morphology (page 8) are handled with gloves, in a well-ventilated area, and are labelled with their hazards. Read the safety data sheet of every chemical you use.
Centrifuges
Balance tubes opposite each other, use sealed buckets or caps for semen, and never open the lid until the rotor has stopped. Know whether a protocol is written in relative centrifugal force (g) or revolutions per minute; they are not the same (page 11).
Liquid nitrogen
Liquid nitrogen causes cold burns and, in a closed room, can displace oxygen. You will not handle it until Day 9, after reading page 48.
Protecting gametes and embryos
- Keep gametes warm: use heated stages and pre-warmed media, and keep dishes out of the incubator for as short a time as possible.
- Limit light exposure under the microscope.
- Use only sterile, embryo-tested consumables, and never reuse a pipette between patients.
- Open and close incubator doors briefly and only when you need to.
Witnessing
A mix-up of gametes or embryos is the most serious error an ART laboratory can make. Witnessing is the system that prevents it. At every critical step a second trained person independently checks that the right material is going to the right place, and both sign the record at the time. Some laboratories also use electronic witnessing with barcodes or radio-frequency tags (page 60).
Critical steps include receiving a sample, moving material from one container to another, insemination or ICSI, transfer, and placing anything into or removing anything from cryo-storage.
At the bench
A witnessed step at the andrology bench runs like this:
- Clear the bench. Only one patient's material is ever open in a workspace at a time.
- Label every new tube or dish on its body, not only on the lid, before any material goes in, with at least two identifiers (for example full name and a unique number).
- Call your witness. Read the identifiers aloud from the source container and the new container; the witness reads them too, from the containers, not from the request form.
- Transfer the material while the witness watches.
- Both of you sign or initial the worksheet with the time.
- Close and put away the first patient's material before you start the next.
Common errors
- Labelling the lid only: lids get swapped.
- Pre-labelling a full rack of tubes for the day, then picking up the wrong one.
- A "witness" who signs without looking at the containers.
- Two patients' samples open on the same bench "just for a minute".
- Leaving a dish on a cold surface while you answer a question.
Check yourself
- Why must perfume and scented creams be kept out of the IVF laboratory?
- List four critical steps that need a witness.
- What should the witness read the identifiers from?
- Why is a lid-only label dangerous?
Questions on this page
Do I need a witness for a semen analysis?
Identity checks matter at every step. In most laboratories the sample is checked at reception and witnessed whenever it is moved into a new container for preparation or use in treatment. Follow your laboratory's written witnessing points.
Why is mouth pipetting forbidden?
Semen and follicular fluid can carry infections such as hepatitis B, hepatitis C and HIV. Mechanical pipetting devices remove this route of infection.
The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.