IVF centre in Goa
Consultations in Panjim · Margao · Mapusa · Vasco
Call
Page 69 of 72Genesis ART Textbook
Part 6: Clinical ART for doctors · Doctor programmes
Page 69 of 72

The IUI procedure

On this page you will learn

What IUI does

Intrauterine insemination places a washed, concentrated sample of motile sperm in the uterine cavity close to the time of ovulation. It bypasses the cervix and puts more motile sperm near the tubes than intercourse would. It needs at least one open tube and an adequate prepared sample (page 66). The laboratory preparation by swim-up or density gradient, and the post-wash assessment, are on pages 10 to 14.

Timing

IUI is timed to ovulation. In a monitored cycle (page 64), when the lead follicle is mature, a trigger is often given and insemination is planned for the following day, at a time set by the unit's protocol. Alternatively, a natural LH surge detected by urine or blood testing is used. The semen sample is produced, prepared and used within the time window that the laboratory protocol sets. Tell the laboratory the planned time well in advance.

Identity: the most important step

An IUI with the wrong sample is a serious and irreversible error. The witnessing principles on pages 3 and 55 apply in full. The man's identity is checked when the sample is received; the prepared tube carries both partners' identifiers; and before insemination, the clinician, the embryologist and the woman confirm the identifiers together, aloud, against the request form and her own statement of her name and date of birth. If anything does not match, stop.

At the bench: performing the IUI

  1. Confirm the woman's identity, explain the procedure, and check written consent is on file (page 71).
  2. Receive the prepared sample from the laboratory and complete the witnessed identity check aloud. Note the post-wash report: volume, concentration and motility.
  3. Position her comfortably in the lithotomy position; a chaperone is present.
  4. Insert a sterile speculum and visualise the cervix. Gently clean away mucus from the external os with sterile saline or culture medium, not antiseptic, which can harm sperm.
  5. Load the sample into the sterile insemination catheter on a syringe, drawing a little air behind it and avoiding bubbles within the sample. Keep it at room temperature and protected from light and heat.
  6. Pass the catheter gently through the cervical canal, following its curve, to just past the internal os. Do not touch the fundus. If the canal is difficult, use a different catheter, straighten the angle with gentle traction, or ask the supervisor; never force it.
  7. Inject the sample slowly over several seconds. Wait a few seconds, then withdraw the catheter slowly.
  8. Check the catheter tip for blood or retained sample and return it to the laboratory if the protocol asks for a check.
  9. Remove the speculum. She may rest briefly, then resume normal activity.

Afterwards

Tell the couple that mild cramping or slight spotting can occur, and what symptoms should prompt a call: fever, increasing pain or heavy bleeding. Give the plan for luteal support if used and the date of the pregnancy test. In stimulated cycles, remind them of the warning signs on page 68.

Records

Record the date and time, cycle details, the post-wash parameters, the catheter used, the ease of the procedure, any bleeding, the names of the clinician and witness, and the follow-up plan. The laboratory keeps its own record of preparation and handover; the two should agree.

Common errors

Check yourself

  1. Who takes part in the identity check before insemination, and what is compared?
  2. Why is antiseptic not used on the cervix before IUI?
  3. How far should the catheter be passed, and what do you do if it will not pass?
  4. List six items that belong in the IUI record.

Contents and reading plan

Questions on this page

Is IUI painful?

Most women feel only mild discomfort, similar to a smear test. Some have mild cramping or slight spotting afterwards.

What happens if the identity check does not match?

The procedure stops until the discrepancy is resolved. A sample is never used if any identifier does not match.

Where does the laboratory part of IUI appear in this book?

Sample preparation and post-wash assessment are covered on pages 10 to 14.

The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.