The andrology bench: safety, labelling and witnessing

On this page you will learn

Every sample is a biohazard

Semen may carry viruses and bacteria, and nobody can tell which sample does. Treat every sample as infectious. Wear gloves and a laboratory coat; add a mask and eye protection when splashes are possible. Never eat, drink or use your phone at the bench. Wash your hands when you leave it.

Source: 2021, World Health Organization - WHO laboratory manual for the examination and processing of human semen, sixth edition, sections 5.1.1.2 and 8.2

Sterile working

For treatment, every item that touches the sample must be sterile and safe for sperm: collection pots, tubes, pipettes and media. Commercial media made and tested for assisted reproduction are used, within their expiry date. Open sterile items inside the cabinet and nowhere else, and never touch a pipette tip or the inside of a tube cap.

Work is done in a vertical laminar-flow cabinet, which blows filtered air down over the work surface. Keep the front grille clear, work towards the middle and move slowly so that the air flow is not broken. Use a mechanical pipetting aid; mouth pipetting is never allowed. Use gloves without powder.

Source: Dec 2015, ESHRE Guideline Group on good practice in IVF labs - Revised guidelines for good practice in IVF laboratories (2015)

Source: 2021, World Health Organization - WHO laboratory manual for the examination and processing of human semen, sixth edition, section 5.2

Temperature

Sperm should not meet extremes of temperature. Keep samples between 20 °C and 37 °C from collection onwards. Media and gradient are warmed to the temperature the product sheet and the Heartbeats lab standard operating procedure (SOP) set before they meet the sample. Check the warm block or incubator reading at the start of each session and write it in the quality-control log.

Source: Dec 2015, ESHRE Guideline Group on good practice in IVF labs - Revised guidelines for good practice in IVF laboratories (2015)

Receiving a sample

The man is asked to state his own full name and date of birth, which are checked against the request form and the pot label. The reception record then notes:

Source: Dec 2015, ESHRE Guideline Group on good practice in IVF labs - Revised guidelines for good practice in IVF laboratories (2015)

The identity chain

Each couple and each treatment cycle has a unique code. Every tube that will hold their sample is labelled permanently, on its body, with that code and the date, before any material goes in. One couple's material is open in the cabinet at a time. When material moves from one container to another, a second person, the witness, checks the labels on both containers. The two of you then record the time, the operator and the witness.

  1. Label the new tube on its body, not on the lid.
  2. Call the witness before you move anything.
  3. Both read the identifiers aloud from the old and the new containers.
  4. Transfer the material while the witness watches.
  5. Both sign the worksheet, with the time.

Source: Dec 2015, ESHRE Guideline Group on good practice in IVF labs - Revised guidelines for good practice in IVF laboratories (2015)

At the bench

Set up your own workstation: clean the cabinet, lay out sterile items, record the temperatures. Then label and witness a training sample through two tube changes. House values for cleaning agents, temperatures and records: follow the Heartbeats lab SOP. Your logbook row for the day is signed by you and by the faculty member who watched you.

Common mistakes

Key points

Check yourself

Answer in your head first, then tap a question to see the short answer.

1. Why are tubes spun capped and in sealed buckets?

To keep aerosols from a possibly infectious sample inside the centrifuge.

2. What two things does a man state when he hands in a sample?

His full name and date of birth, checked against the form and the label.

3. List four items on the reception record.

Container type, time and place of collection, abstinence days, completeness of the ejaculate (also fever or medicines, arrival time, start of preparation).

4. When is a witness needed at the bench?

Whenever material moves from one container to another, and at first identification and final hand-over.

5. Why is a label on the lid alone dangerous?

Lids can be swapped between tubes, so the label no longer matches the contents.

6. From page 23: what is the time limit for starting preparation?

One hour from collection.

Training note. Training content for registered medical practitioners. Trainees observe all patient care; they do not treat patients during the programme.

Contents and reading plan

Questions on this page

Do doctors handle real patient samples during the IUI programme?

Doctor trainees prepare training samples at the bench under supervision. Patient care, including the IUI itself, is observed.

What is a witness at the bench?

A second trained person who checks the labels on both containers whenever a sample moves, and signs the record with the operator.

The Genesis Doctors' Textbook is teaching text for registered medical practitioners on the doctor programmes of the Genesis ART Training Academy. It is not treatment advice and gives no medicine doses; trainees observe all patient care, ultrasound scans are watched only (PCPNDT Act), and bench skills are practised under supervision. Page numbers never change.